Customization: | Available |
---|---|
After-sales Service: | 24-Hour After-Sale Technical Support, Mail, Video |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Application:
This robotic provides fully automatic tensile test, including specimen loading, cross-section measuring, testing, specimen unloading, and data processing.
Operators prepare specimens and position specimen on specimen rack. All processes are automatic: Robot will pick up specimen to measure cross-section, align the specimen and mount on grip, extensometer automatic gauge length adjusting, test, test data judging and processing, and collect broken specimens. Without changing any accessories (such as fixtures, etc.) of the test machine and without any adjustment or setting by the operator, the test specimens of various specifications can be continuously tested under different tensile conditions.
Item |
Name |
HST-E250-AR |
HST-E300-AR |
Machine |
Capacity |
250kN |
300 |
Force range |
0.4%-100%FS |
||
Accuracy |
Class 0.3 |
||
Force reading accuracy |
±0.3% |
||
Reversibility |
±0.75% |
||
Repeatability |
±0.3% |
||
Force resolution |
0.6N |
||
Overload |
120% |
||
displacement accuracy |
±0.5% |
||
Position resolution |
0.02µm |
||
Force loading rate |
0.005~5%FS/s |
||
Force loading accuracy |
±1% of setting |
||
Horizontal test space |
650mm |
||
Vertical test space |
700mm |
||
Crosshead speed |
0.001~500mm/min |
||
Crosshead speed accuracy |
Speed<0.01mm/min, within ±1% of setting, Speed≥0.01mm/min, within ±0.2% of setting |
||
Constant force and displacement control range |
0.5%~100%FS/s |
||
Constant force and displacement control accuracy |
Setting value≥10%FS, within ±0.1% of setting, Setting value<10%FS, within ±0.1% of setting |
||
Automatic axial extensometer |
Gauge length |
15~205mm |
|
Gauge length accuracy |
0.5% or 0.1mm, whichever is bigger |
||
Maximum travel |
80mm |
||
Resolution |
0.0005mm |
||
Specimen clamping range |
5~50mm |
||
Accuracy |
Class 0.5 |
||
Pneumatic shoulder grip |
Clamp type |
Shoulder type, pneumatic action |
|
Center alignment accuracy |
0.2mm |
||
Clamping range |
Gripping end: Ф20~ Ф25mm |
||
Specimen rack |
Maximum specimen quantities |
60 pieces |
|
Specimen rack numbers |
4 |
||
Specimen length |
120~250mm |
||
Broken specimen rack |
Maximum specimen quantities |
60 |
|
Specimen rack numbers |
4 |
||
Robot |
Type |
Asea Brown Boveri joint type |
|
Handling weight |
6kg |
||
Maximum reach |
1450mm |
||
Degree of freedom |
6 |
||
Positioning repeatability |
0.02mm |
||
Speed |
21 pcs/hour |
||
Cross-section measurement device |
Measuring range |
Ф5 ~ Ф25mm |
|
Resolution |
0.02mm |
||
Specimen |
Round specimen |
Gripping end: Ф20~ Ф25mm, parallel length Ф10, Ф14mm, Length: 120~250mm |